A PC with no i8042 (port 0x64 reads 0xFF) hung in a drain loop that never ended: now detected and skipped, every drain bounded. Still open from S3: the legacy PIC is written with no check that it exists.
Reconstructed 2026-11-06 from the project record; Gitea dates every issue by when it is created.
**Closed 2026-10-14** · `FABRIC-3.md` §XLI; `boards/BRINGUP.md` A3, S3
A PC with no i8042 (port 0x64 reads 0xFF) hung in a drain loop that never ended: now detected and skipped, every drain bounded. Still open from S3: the legacy PIC is written with no check that it exists.
<sub>Reconstructed 2026-11-06 from the project record; Gitea dates every issue by when it is created.</sub>
rajames
added this to the Board bring-up milestone 2026-11-06 19:06:03 +00:00
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
Closed 2026-10-14 ·
FABRIC-3.md§XLI;boards/BRINGUP.mdA3, S3A PC with no i8042 (port 0x64 reads 0xFF) hung in a drain loop that never ended: now detected and skipped, every drain bounded. Still open from S3: the legacy PIC is written with no check that it exists.
Reconstructed 2026-11-06 from the project record; Gitea dates every issue by when it is created.