Captain Bob, 2026-11-14: the standard first, in the order 79, 83, ANS, then v3; the texts in the repository as references. FORTH-79 and FORTH-83 from the University of Vienna's FORTH archive (complang.tuwien.ac.at), ANS Forth's final draft (dpANS) from Taygeta, as fetched, with their sources in docs/reference/standards/README.md. Not pushed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_017RzZgrf7V7Zk2iczBXDRbm
632 lines
21 KiB
HTML
632 lines
21 KiB
HTML
<HTML><HEAD>
|
|
<TITLE>DPANS94</TITLE>
|
|
</HEAD>
|
|
|
|
<BODY>
|
|
<table width=100%>
|
|
<tr>
|
|
<td align=left>
|
|
<a href=dpansd.htm><img src=left.gif
|
|
width=26 height=26 align=ALIGN border=0></a>
|
|
<a href=dpansf.htm><img src=right.gif
|
|
width=26 height=26 align=ALIGN border=0></a>
|
|
</td>
|
|
<td align=right>
|
|
<a href=dpans.htm#toc><img src=up.gif
|
|
width=26 height=26 align=ALIGN border=0></a>
|
|
<a name=E.>Table of Contents</a>
|
|
</td>
|
|
</tr>
|
|
</table>
|
|
<p>
|
|
<hr size=4>
|
|
|
|
<H1>E. ANS Forth portability guide (informative
|
|
annex)</H1>
|
|
|
|
|
|
<hr>
|
|
<A name=E.1>
|
|
<H1>E.1 Introduction</H1>
|
|
</a>
|
|
|
|
The most popular architectures used to implement Forth have had
|
|
byte-addressed memory, 16-bit operations, and two's-complement number
|
|
representation. The Forth-83 Standard dictates that these particular
|
|
features must be present in a Forth-83 Standard system and that Forth-83
|
|
programs may exploit these features freely.
|
|
|
|
<P>
|
|
|
|
However, there are many beasts in the architectural jungle that are bit
|
|
addressed or cell addressed, or prefer 32-bit operations, or represent
|
|
numbers in one's complement. Since one of Forth's strengths is its
|
|
usefulness in <B>strange</B> environments on <B>unusual</B> hardware
|
|
with <B>peculiar</B> features, it is important that a Standard Forth run
|
|
on these machines too.
|
|
|
|
<P>
|
|
|
|
A primary goal of the ANS Forth Standard is to increase the types of
|
|
machines that can support a Standard Forth. This is accomplished by
|
|
allowing some key Forth terms to be implementation-defined (e.g., how
|
|
big is a cell?) and by providing Forth operators (words) that conceal
|
|
the implementation. This frees the implementor to produce the Forth
|
|
system that most effectively utilizes the native hardware. The machine
|
|
independent operators, together with some programmer discipline, enable
|
|
a programmer to write Forth programs that work on a wide variety of
|
|
machines.
|
|
|
|
<P>
|
|
|
|
The remainder of this Annex provides guidelines for writing portable ANS
|
|
Forth programs. The first section describes ways to make a program
|
|
hardware independent. It is difficult for someone familiar with only
|
|
one machine architecture to imagine the problems caused by transporting
|
|
programs between dissimilar machines. Consequently, examples of
|
|
specific architectures with their respective problems are given. The
|
|
second section describes assumptions about Forth implementations that
|
|
many programmers make, but can't be relied upon in a portable program.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.2>
|
|
<H1>E.2 Hardware peculiarities</H1>
|
|
</a>
|
|
|
|
|
|
<hr>
|
|
<A name=E.2.1>
|
|
<H2>E.2.1 Data/memory abstraction</H2>
|
|
</a>
|
|
|
|
Data and memory are the stones and mortar of program construction.
|
|
Unfortunately, each computer treats data and memory differently. The
|
|
ANS Forth Systems Standard gives definitions of data and memory that
|
|
apply to a wide variety of computers. These definitions give us a way
|
|
to talk about the common elements of data and memory while ignoring the
|
|
details of specific hardware. Similarly, ANS Forth programs that use
|
|
data and memory in ways that conform to these definitions can also
|
|
ignore hardware details. The following sections discuss the definitions
|
|
and describe how to write programs that are independent of the
|
|
data/memory peculiarities of different computers.
|
|
<P>
|
|
|
|
|
|
|
|
<hr>
|
|
<A name=E.2.2>
|
|
<H2>E.2.2 Definitions</H2>
|
|
</a>
|
|
|
|
Three terms defined by ANS Forth are address unit, cell, and character.
|
|
The address space of an ANS Forth system is divided into an array of
|
|
address units; an address unit is the smallest collection of bits that
|
|
can be addressed. In other words, an address unit is the number of bits
|
|
spanned by the addresses addr and addr+1. The most prevalent machines
|
|
use 8-bit address units. Such <B>byte addressed</B> machines include
|
|
the Intel 8086 and Motorola 68000 families. However, other address unit
|
|
sizes exist. There are machines that are bit addressed and machines
|
|
that are 4-bit nibble addressed. There are also machines with address
|
|
units larger than 8-bits. For example, several Forth-in-hardware
|
|
computers are cell addressed.
|
|
|
|
<P>
|
|
|
|
The cell is the fundamental data type of a Forth system. A cell can be
|
|
a single-cell integer or a memory address. Forth's parameter and return
|
|
stacks are stacks of cells. Forth-83 specifies that a cell is 16-bits.
|
|
In ANS Forth the size of a cell is an implementation-defined number of
|
|
address units. Thus, an ANS Forth implemented on a 16-bit
|
|
microprocessor could use a 16-bit cell and an implementation on a 32-bit
|
|
machine could use a 32-bit cell. Also 18-bit machines, 36-bit machines,
|
|
etc., could support ANS Forth systems with 18 or 36-bit cells
|
|
respectively. In all of these systems,
|
|
<a href=dpans6.htm#6.1.1290>DUP</a>
|
|
does the same thing: it
|
|
duplicates the top of the data stack.
|
|
! (<a href=dpans6.htm#6.1.0010>store</a>)
|
|
behaves consistently
|
|
too: given two cells on the data stack it stores the second cell in the
|
|
memory location designated by the top cell.
|
|
|
|
<P>
|
|
|
|
Similarly, the definition of a character has been generalized to be an
|
|
implementation-defined number of address units (but at least eight
|
|
bits). This removes the need for a Forth implementor to provide 8-bit
|
|
characters on processors where it is inappropriate. For example, on an
|
|
18-bit machine with a 9-bit address unit, a 9-bit character would be
|
|
most convenient. Since, by definition, you can't address anything
|
|
smaller than an address unit, a character must be at least as big as an
|
|
address unit. This will result in big characters on machines with large
|
|
address units. An example is a 16-bit cell addressed machine where a
|
|
16-bit character makes the most sense.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.2.3>
|
|
<H2>E.2.3 Addressing memory</H2>
|
|
</a>
|
|
|
|
ANS Forth eliminates many portability problems by using the above
|
|
definitions. One of the most common portability problems is addressing
|
|
successive cells in memory. Given the memory address of a cell, how do
|
|
you find the address of the next cell? In Forth-83 this is easy: 2 + .
|
|
This code assumes that memory is addressed in 8-bit units (bytes) and a
|
|
cell is 16-bits wide. On a byte-addressed machine with 32-bit cells the
|
|
code to find the next cell would be 4 + . The code would be 1+ on a
|
|
cell-addressed processor and 16+ on a bit-addressed processor with
|
|
16-bit cells. ANS Forth provides a next-cell operator named
|
|
<a href=dpans6.htm#6.1.0880>CELL+</a>
|
|
that
|
|
can be used in all of these cases. Given an address, CELL+ adjusts the
|
|
address by the size of a cell (measured in address units). A related
|
|
problem is that of addressing an array of cells in an arbitrary order.
|
|
A defining word to create an array of cells using Forth-83 would be:
|
|
|
|
|
|
<PRE>
|
|
: ARRAY CREATE 2* ALLOT DOES> SWAP 2* + ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
Use of
|
|
<a href=dpans6.htm#6.1.0320>2*</a>
|
|
to scale the array index assumes byte addressing and 16-bit
|
|
cells again. As in the example above, different versions of the code
|
|
would be needed for different machines. ANS Forth provides a portable
|
|
scaling operator named
|
|
<a href=dpans6.htm#6.1.0890>CELLS</a>.
|
|
Given a number n, CELLS returns the
|
|
number of address units needed to hold n cells. A portable definition
|
|
of array is:
|
|
|
|
<PRE>
|
|
: ARRAY CREATE CELLS ALLOT
|
|
DOES> SWAP CELLS + ;
|
|
</PRE>
|
|
<P>
|
|
|
|
There are also portability problems with addressing arrays of
|
|
characters. In Forth-83 (and in the most common ANS Forth
|
|
implementations), the size of a character will equal the size of an
|
|
address unit. Consequently addresses of successive characters in memory
|
|
can be found using
|
|
<a href=dpans6.htm#6.1.0290>1+</a>
|
|
and scaling indices into a character array is a
|
|
no-op (i.e., 1 *). However, there are cases where a character is larger
|
|
than an address unit. Examples include (1) systems with small address
|
|
units (e.g., bit- and nibble-addressed systems), and (2) systems with
|
|
large character sets (e.g., 16-bit characters on a byte-addressed
|
|
machine).
|
|
<a href=dpans6.htm#6.1.0897>CHAR+</a>
|
|
and
|
|
<a href=dpans6.htm#6.1.0898>CHARS</a>
|
|
operators, analogous to CELL+ and CELLS are
|
|
available to allow maximum portability.
|
|
<P>
|
|
|
|
ANS Forth generalizes the definition of some Forth words that operate on
|
|
chunks of memory to use address units. One example is
|
|
<a href=dpans6.htm#6.1.0710>ALLOT</a>. By
|
|
prefixing ALLOT with the appropriate scaling operator (CELLS, CHARS,
|
|
etc.), space for any desired data structure can be allocated (see
|
|
definition of array above). For example:
|
|
|
|
<PRE>
|
|
CREATE ABUFFER 5 CHARS ALLOT ( allot 5 character buffer)
|
|
</PRE>
|
|
<P>
|
|
|
|
The memory-block-move
|
|
word also uses address units:
|
|
|
|
|
|
<PRE>
|
|
source destination 8 CELLS MOVE ( move 8 cells)
|
|
</PRE>
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.2.4>
|
|
<H2>E.2.4 Alignment problems</H2>
|
|
</a>
|
|
|
|
Not all addresses are created equal. Many processors have restrictions
|
|
on the addresses that can be used by memory access instructions. This
|
|
Standard does not require an implementor of an ANS Forth to make
|
|
alignment transparent; on the contrary, it requires (in
|
|
<a href=dpans3.htm#3.3.3.1>Section 3.3.3.1</a>
|
|
Address alignment) that an ANS Forth program assume that character and
|
|
cell alignment may be required.
|
|
|
|
<P>
|
|
|
|
One of the most common problems caused by alignment restrictions is in
|
|
creating tables containing both characters and cells. When
|
|
, (<a href=dpans6.htm#6.1.0150>comma</a>) or
|
|
<a href=dpans6.htm#6.1.0860>C,</a>
|
|
is used to initialize a table, data is stored at the data-space
|
|
pointer. Consequently, it must be suitably aligned. For example, a
|
|
non-portable table definition would be:
|
|
|
|
|
|
<PRE>
|
|
CREATE ATABLE 1 C, X , 2 C, Y ,
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
On a machine that restricts 16-bit fetches to even addresses,
|
|
<a href=dpans6.htm#6.1.1000>CREATE</a>
|
|
would leave the data space pointer at an even address, the 1 C, would
|
|
make the data space pointer odd, and , (comma) would violate the address
|
|
restriction by storing X at an odd address. A portable way to create
|
|
the table is:
|
|
|
|
|
|
<PRE>
|
|
CREATE ATABLE 1 C, ALIGN X , 2 C, ALIGN Y ,
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<a href=dpans6.htm#6.1.0705>ALIGN</a>
|
|
adjusts the data space pointer to the first aligned address
|
|
greater than or equal to its current address. An aligned address is
|
|
suitable for storing or fetching characters, cells, cell pairs, or
|
|
double-cell numbers.
|
|
|
|
<P>
|
|
|
|
After initializing the table, we would also like to read values from the
|
|
table. For example, assume we want to fetch the first cell, X, from the
|
|
table. ATABLE CHAR+ gives the address of the first thing after the
|
|
character. However this may not be the address of X since we aligned
|
|
the dictionary pointer between the C, and the ,. The portable way to
|
|
get the address of X is:
|
|
|
|
|
|
<PRE>
|
|
ATABLE CHAR+ ALIGNED
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<a href=dpans6.htm#6.1.0706>ALIGNED</a>
|
|
adjusts the address on top of the stack to the first aligned
|
|
address greater than or equal to its current value.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.3>
|
|
<H1>E.3 Number representation</H1>
|
|
</a>
|
|
|
|
Different computers represent numbers in different ways. An awareness
|
|
of these differences can help a programmer avoid writing a program that
|
|
depends on a particular representation.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.3.1>
|
|
<H2>E.3.1 Big endian vs. little endian</H2>
|
|
</a>
|
|
|
|
The constituent bits of a number in memory are kept in different orders
|
|
on different machines. Some machines place the most-significant part of
|
|
a number at an address in memory with less-significant parts following
|
|
it at higher addresses. Other machines do the opposite the
|
|
least-significant part is stored at the lowest address. For example,
|
|
the following code for a 16-bit 8086 <B>little endian</B> Forth would
|
|
produce the answer 34 (hex):
|
|
|
|
|
|
<PRE>
|
|
VARIABLE FOO HEX 1234 FOO ! FOO C@
|
|
</PRE>
|
|
<P>
|
|
|
|
The same code on a 16-bit 68000 <B>big endian</B> Forth would produce
|
|
the answer 12 (hex). A portable program cannot exploit the
|
|
representation of a number in memory.
|
|
|
|
<P>
|
|
|
|
A related issue is the representation of cell pairs and double-cell
|
|
numbers in memory. When a cell pair is moved from the stack to memory
|
|
with
|
|
<a href=dpans6.htm#6.1.0310>2!</a>,
|
|
the cell that was on top of the stack is placed at the lower
|
|
memory address. It is useful and reasonable to manipulate the
|
|
individual cells when they are in memory.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.3.2>
|
|
<H2>E.3.2 ALU organization</H2>
|
|
</a>
|
|
|
|
Different computers use different bit patterns to represent integers.
|
|
Possibilities include binary representations (two's complement, one's
|
|
complement, sign magnitude, etc.) and decimal representations (BCD,
|
|
etc.). Each of these formats creates advantages and disadvantages in
|
|
the design of a computer's arithmetic logic unit (ALU). The most
|
|
commonly used representation, two's complement, is popular because of
|
|
the simplicity of its addition and subtraction algorithms.
|
|
|
|
<P>
|
|
|
|
Programmers who have grown up on two's complement machines tend to
|
|
become intimate with their representation of numbers and take some
|
|
properties of that representation for granted. For example, a trick to
|
|
find the remainder of a number divided by a power of two is to mask off
|
|
some bits with
|
|
<a href=dpans6.htm#6.1.0720>AND</a>.
|
|
A common application of this trick is to test a
|
|
number for oddness using 1 AND. However, this will not work on a one's
|
|
complement machine if the number is negative (a portable technique is 2
|
|
<a href=dpans6.htm#6.1.1890>MOD</a>).
|
|
|
|
<P>
|
|
|
|
The remainder of this section is a (non-exhaustive) list of things to
|
|
watch for when portability between machines with binary representations
|
|
other than two's complement is desired.
|
|
|
|
<P>
|
|
|
|
To convert a single-cell number to a double-cell number, ANS Forth
|
|
provides the operator
|
|
<a href=dpans6.htm#6.1.2170>S>D</a>.
|
|
To convert a double-cell number to
|
|
single-cell, Forth programmers have traditionally used
|
|
<a href=dpans6.htm#6.1.1260>DROP</a>.
|
|
However,
|
|
this trick doesn't work on sign-magnitude machines. For portability a
|
|
<a href=dpans8.htm#8.6.1.1140>D>S</a>
|
|
operator is available. Converting an unsigned single-cell number to
|
|
a double-cell number can be done portably by pushing a zero on the
|
|
stack.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.4>
|
|
<H1>E.4 Forth system implementation</H1>
|
|
</a>
|
|
|
|
During Forth's history, an amazing variety of implementation techniques
|
|
have been developed. The ANS Forth Standard encourages this diversity
|
|
and consequently restricts the assumptions a user can make about the
|
|
underlying implementation of an ANS Forth system. Users of a particular
|
|
Forth implementation frequently become accustomed to aspects of the
|
|
implementation and assume they are common to all Forths. This section
|
|
points out many of these incorrect assumptions.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.4.1>
|
|
<H2>E.4.1 Definitions</H2>
|
|
</a>
|
|
|
|
Traditionally, Forth definitions have consisted of the name of the Forth
|
|
word, a dictionary search link, data describing how to execute the
|
|
definition, and parameters describing the definition itself. These
|
|
components are called the name, link, code, and parameter fields. No
|
|
method for accessing these fields has been found that works across all
|
|
of the Forth implementations currently in use. Therefore, ANS Forth
|
|
severely restricts how the fields may be used. Specifically, a portable
|
|
ANS Forth program may not use the name, link, or code field in any way.
|
|
Use of the parameter field (renamed to data field for clarity) is
|
|
limited to the operations described below.
|
|
|
|
<P>
|
|
|
|
Only words defined with
|
|
<a href=dpans6.htm#6.1.1000>CREATE</a>
|
|
or with other defining words that call
|
|
CREATE have data fields. The other defining words in the Standard
|
|
(<a href=dpans6.htm#6.1.2410>VARIABLE</a>,
|
|
<a href=dpans6.htm#6.1.0950>CONSTANT</a>,
|
|
<a href=dpans6.htm#6.1.0450>:</a>,
|
|
etc.) might not be implemented with CREATE.
|
|
Consequently, a Standard Program must assume that words defined by
|
|
VARIABLE, CONSTANT, : , etc., may have no data fields. There is no way
|
|
for a Standard Program to modify the value of a constant or to change
|
|
the meaning of a colon definition. The
|
|
<a href=dpans6.htm#6.1.1250>DOES</a>>
|
|
part of a defining word
|
|
operates on a data field. Since only CREATEd words have data fields,
|
|
DOES> can only be paired with CREATE or words that call CREATE.
|
|
|
|
<P>
|
|
|
|
In ANS Forth,
|
|
<a href=dpans6.htm#6.1.1550>FIND</a>,
|
|
<a href=dpans6.htm#6.1.2510>[']</a> and
|
|
' (<a href=dpans6.htm#6.1.0070>tick</a>)
|
|
return an unspecified entity called
|
|
an <B>execution token</B>. There are only a few things that may be done
|
|
with an execution token. The token may be passed to
|
|
<a href=dpans6.htm#6.1.1370>EXECUTE</a>
|
|
to execute
|
|
the word ticked or compiled into the current definition with
|
|
<a href=dpans6.htm#6.2.0945>COMPILE,</a>.
|
|
The token can also be stored in a variable and used later. Finally, if
|
|
the word ticked was defined via CREATE,
|
|
<a href=dpans6.htm#6.1.0550>>BODY</a>
|
|
converts the execution
|
|
token into the word's data-field address.
|
|
|
|
<P>
|
|
|
|
One thing that definitely cannot be done with an execution token is use
|
|
<a href=dpans6.htm#6.1.0010>!</a>
|
|
or
|
|
<a href=dpans6.htm#6.1.0150>,</a>
|
|
to store it into the object code of a Forth definition. This
|
|
technique is sometimes used in implementations where the object code is
|
|
a list of addresses (threaded code) and an execution token is also an
|
|
address. However, ANS Forth permits native code implementations where
|
|
this will not work.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.4.2>
|
|
<H2>E.4.2 Stacks</H2>
|
|
</a>
|
|
|
|
In some Forth implementations, it is possible to find the address of a
|
|
stack in memory and manipulate the stack as an array of cells. This
|
|
technique is not portable, however. On some systems, especially
|
|
Forth-in-hardware systems, the stacks might be in a part of memory that
|
|
can't be addressed by the program or might not be in memory at all.
|
|
Forth's parameter and return stacks must be treated as stacks.
|
|
|
|
<P>
|
|
|
|
A Standard Program may use the return stack directly only for
|
|
temporarily storing values. Every value examined or removed from the
|
|
return stack using
|
|
<a href=dpans6.htm#6.1.2070>R@</a>,
|
|
<a href=dpans6.htm#6.1.2060>R></a>, or
|
|
<a href=dpans6.htm#6.2.0410>2R></a>
|
|
must have been put on the stack
|
|
explicitly using
|
|
<a href=dpans6.htm#6.1.0580>>R</a> or
|
|
<a href=dpans6.htm#6.2.0340>2>R</a>.
|
|
Even this must be done carefully since the
|
|
system may use the return stack to hold return addresses and
|
|
loop-control parameters.
|
|
<a href=dpans3.htm#3.2.3.3>Section 3.2.3.3</a> Return stack of the Standard
|
|
has a list of restrictions.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.5>
|
|
<H1>E.5 ROMed application disciplines and conventions</H1>
|
|
</a>
|
|
|
|
When a Standard System provides a data space which is uniformly readable
|
|
and writeable we may term this environment <B>RAM-only</B>.
|
|
|
|
<P>
|
|
|
|
Programs designed for ROMed application must divide data space into at
|
|
least two parts: a writeable and readable uninitialized part, called
|
|
<B>RAM</B>, and a read-only initialized part, called <B>ROM</B>. A
|
|
third possibility, a writeable and readable initialized part, normally
|
|
called <B>initialized RAM</B>, is not addressed by this discipline. A
|
|
Standard Program must explicitly initialize the RAM data space as
|
|
needed.
|
|
|
|
<P>
|
|
|
|
The separation of data space into RAM and ROM is meaningful only during
|
|
the generation of the ROMed program. If the ROMed program is itself a
|
|
standard development system, it has the same taxonomy as an ordinary
|
|
RAM-only system.
|
|
|
|
<P>
|
|
|
|
The words affected by conversion from a RAM-only to a mixed RAM and ROM
|
|
environment are:
|
|
|
|
<p>
|
|
, (<a href=dpans6.htm#6.1.0150>comma</a>)
|
|
<a href=dpans6.htm#6.1.0705>ALIGN</a>
|
|
<a href=dpans6.htm#6.1.0706>ALIGNED</a>
|
|
<a href=dpans6.htm#6.1.0710>ALLOT</a>
|
|
<a href=dpans6.htm#6.1.0860>C,</a>
|
|
<a href=dpans6.htm#6.1.1000>CREATE</a>
|
|
<a href=dpans6.htm#6.1.1650>HERE</a>
|
|
<a href=dpans6.htm#6.2.2395>UNUSED</a>
|
|
<P>
|
|
|
|
(<a href=dpans6.htm#6.1.2410>VARIABLE</a> always
|
|
accesses the RAM data space.)
|
|
|
|
<P>
|
|
|
|
With the exception of , (comma) and C,
|
|
these words are meaningful in both RAM
|
|
and ROM data space.
|
|
|
|
<P>
|
|
|
|
To select the data space, these words could be preceded by selectors RAM
|
|
and ROM. For example:
|
|
|
|
|
|
<PRE>
|
|
ROM CREATE ONES 32 ALLOT ONES 32 1 FILL RAM
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
would create a table of ones in the ROM data space. The storage of data
|
|
into RAM data space when generating a program for ROM would be an
|
|
ambiguous condition.
|
|
|
|
<P>
|
|
|
|
A straightforward implementation of these selectors would maintain
|
|
separate address counters for each space. A counter value would be
|
|
returned by HERE and altered by , (comma), C,, ALIGN, and ALLOT, with
|
|
RAM and ROM simply selecting the appropriate address counter. This
|
|
technique could be extended to additional partitions of the data space.
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<A name=E.6>
|
|
<H1>E.6 Summary</H1>
|
|
</a>
|
|
|
|
The ANS Forth Standard cannot and should not force anyone to write a
|
|
portable program. In situations where performance is paramount, the
|
|
programmer is encouraged to use every trick in the book. On the other
|
|
hand, if portability to a wide variety of systems is needed, ANS Forth
|
|
provides the tools to accomplish this. There is probably no such thing
|
|
as a completely portable program. A programmer, using this guide,
|
|
should intelligently weigh the tradeoffs of providing portability to
|
|
specific machines. For example, machines that use sign-magnitude
|
|
numbers are rare and probably don't deserve much thought. But, systems
|
|
with different cell sizes will certainly be encountered and should be
|
|
provided for. In general, making a program portable clarifies both the
|
|
programmer's thinking process and the final program.
|
|
|
|