Captain Bob, 2026-11-14: the standard first, in the order 79, 83, ANS, then v3; the texts in the repository as references. FORTH-79 and FORTH-83 from the University of Vienna's FORTH archive (complang.tuwien.ac.at), ANS Forth's final draft (dpANS) from Taygeta, as fetched, with their sources in docs/reference/standards/README.md. Not pushed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_017RzZgrf7V7Zk2iczBXDRbm
2044 lines
48 KiB
HTML
2044 lines
48 KiB
HTML
<HTML><HEAD>
|
|
<TITLE>DPANS94</TITLE>
|
|
</HEAD>
|
|
|
|
<BODY>
|
|
<table width=100%>
|
|
<tr>
|
|
<td align=left>
|
|
<a href=dpansa5.htm><img src=left.gif
|
|
width=26 height=26 align=ALIGN border=0></a>
|
|
<a href=dpansa7.htm><img src=right.gif
|
|
width=26 height=26 align=ALIGN border=0></a>
|
|
</td>
|
|
<td align=right>
|
|
<a href=dpans.htm#toc><img src=up.gif
|
|
width=26 height=26 align=ALIGN border=0></a>
|
|
<a name=A.6>Table of Contents</a>
|
|
</td>
|
|
</tr>
|
|
</table>
|
|
<p>
|
|
<hr size=4>
|
|
|
|
<H2>A.6 Glossary</H2>
|
|
|
|
In this and following sections we present rationales for the handling of
|
|
specific words: why we included them, why we placed them in certain word
|
|
sets, or why we specified their names or meaning as we did.
|
|
|
|
<P>
|
|
|
|
Words in this section are organized by word set, retaining their index
|
|
numbers for easy cross-referencing to the glossary.
|
|
|
|
<P>
|
|
|
|
Historically, many Forth systems have been written in Forth. Many of
|
|
the words in Forth originally had as their primary purpose support of
|
|
the Forth system itself. For example, WORD and FIND are often used as
|
|
the principle instruments of the Forth text interpreter, and CREATE in
|
|
many systems is the primitive for building dictionary entries. In
|
|
defining words such as these in a standard way, we have endeavored not
|
|
to do so in such a way as to preclude their use by implementors. One of
|
|
the features of Forth that has endeared it to its users is that the same
|
|
tools that are used to implement the system are available to the
|
|
application programmer - a result of this approach is the compactness
|
|
and efficiency that characterizes most Forth implementations.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1>
|
|
<H3>A.6.1 Core words</H3>
|
|
</a>
|
|
|
|
|
|
|
|
<hr>
|
|
<a name=A.6.1.0070>A.6.1.0070 '</A>
|
|
<P>
|
|
</a>
|
|
|
|
Typical use: <code>... ' name .</code>
|
|
<P>
|
|
|
|
Many Forth systems use a state-smart tick. Many do not. ANS Forth follows
|
|
the usage of Forth-83.
|
|
|
|
<P>
|
|
<code>
|
|
See:
|
|
<a href=dpansa3.htm#A.3.4.3.2>A.3.4.3.2</a> Interpretation semantics,
|
|
<a href=dpansa6.htm#A.6.1.1550>A.6.1.1550 FIND</a>
|
|
</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0080>A.6.1.0080 (</A>
|
|
<P>
|
|
|
|
Typical use: <code>... ( ccc) ...</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0140>A.6.1.0140 +LOOP</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... limit first DO ... step +LOOP ;</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0150>A.6.1.0150 ,</A>
|
|
<P>
|
|
|
|
The use of , (comma) for compiling execution tokens is not portable.
|
|
<P>
|
|
<code>
|
|
See:
|
|
<a href=dpans6.htm#6.2.0945>6.2.0945 COMPILE,</a>
|
|
</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0190>A.6.1.0190 ."</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... ." ccc" ... ;</code>
|
|
<P>
|
|
|
|
An implementation may define interpretation semantics for ." if desired.
|
|
In one plausible implementation, interpreting ." would display the
|
|
delimited message. In another plausible implementation, interpreting ."
|
|
would compile code to display the message later. In still another
|
|
plausible implementation, interpreting ." would be treated as an
|
|
exception. Given this variation a Standard Program may not use ." while
|
|
interpreting. Similarly, a Standard Program may not compile POSTPONE ."
|
|
inside a new word, and then use that word while interpreting.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0320>A.6.1.0320 2*</A>
|
|
<P>
|
|
|
|
Historically, 2* has been implemented on two's-complement machines as a
|
|
logical left-shift instruction. Multiplication by two is an efficient
|
|
side-effect on these machines. However, shifting implies a knowledge of
|
|
the significance and position of bits in a cell. While the name implies
|
|
multiplication, most implementors have used a hardware left shift to
|
|
implement 2*.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0330>A.6.1.0330 2/</A>
|
|
<P>
|
|
|
|
This word has the same common usage and misnaming implications as 2*.
|
|
It is often implemented on two's-complement machines with a hardware
|
|
right shift that propagates the sign bit.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0350>A.6.1.0350 2@</A>
|
|
<P>
|
|
|
|
With 2@ the storage order is specified by the Standard.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0450>A.6.1.0450 :</A>
|
|
<P>
|
|
|
|
Typical use: <code>: name ... ;</code>
|
|
|
|
<P>
|
|
|
|
In Forth-83, this word was specified to alter the search order. This
|
|
specification is explicitly removed in this Standard. We believe that
|
|
in most cases this has no effect; however, systems that allow many
|
|
search orders found the Forth-83 behavior of colon very undesirable.
|
|
|
|
<P>
|
|
|
|
Note that colon does not itself invoke the compiler. Colon sets
|
|
compilation state so that later words in the parse area are compiled.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0460>A.6.1.0460 ;</A>
|
|
<P>
|
|
|
|
|
|
Typical use: <code>: name ... ;</code>
|
|
|
|
<P>
|
|
|
|
One function performed by both ; and ;CODE is to allow the current
|
|
definition to be found in the dictionary. If the current definition was
|
|
created by :NONAME the current definition has no definition name and
|
|
thus cannot be found in the dictionary. If :NONAME is implemented the
|
|
Forth compiler must maintain enough information about the current
|
|
definition to allow ; and ;CODE to determine whether or not any action
|
|
must be taken to allow it to be found.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0550>A.6.1.0550 >BODY</A>
|
|
<P>
|
|
|
|
a-addr is the address that HERE would have returned had it been executed
|
|
immediately after the execution of the CREATE that defined xt.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0680>A.6.1.0680 ABORT"</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... test ABORT" ccc" ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0695>A.6.1.0695 ACCEPT</A>
|
|
<P>
|
|
|
|
Previous standards specified that collection of the input string
|
|
terminates when either a <B>return</B> is received or when +n1
|
|
characters have been received. Terminating when +n1 characters have
|
|
been received is difficult, expensive, or impossible to implement in
|
|
some system environments. Consequently, a number of existing
|
|
implementations do not comply with this requirement. Since line-editing
|
|
and collection functions are often implemented by system components
|
|
beyond the control of the Forth implementation, this Standard imposes no
|
|
such requirement. A Standard Program may only assume that it can
|
|
receive an input string with ACCEPT or
|
|
<a href=dpans6.htm#6.2.1390>EXPECT</a>.
|
|
The detailed sequence of
|
|
user actions necessary to prepare and transmit that line are beyond the
|
|
scope of this Standard.
|
|
|
|
<P>
|
|
|
|
Specification of a non-zero, positive integer count (+n1) for ACCEPT
|
|
allows some implementors to continue their practice of using a zero or
|
|
negative value as a flag to trigger special behavior. Insofar as such
|
|
behavior is outside the Standard, Standard Programs cannot depend upon
|
|
it, but the Technical Committee doesn't wish to preclude it
|
|
unnecessarily. Since actual values are almost always small integers, no
|
|
functionality is impaired by this restriction.
|
|
|
|
<P>
|
|
|
|
ACCEPT and EXPECT perform similar functions. ACCEPT is recommended for
|
|
new programs, and future use of EXPECT is discouraged.
|
|
|
|
<P>
|
|
|
|
It is recommended that all non-graphic characters be reserved for
|
|
editing or control functions and not be stored in the input string.
|
|
|
|
<P>
|
|
|
|
Commonly, when the user is preparing an input string to be transmitted
|
|
to a program, the system allows the user to edit that string and correct
|
|
mistakes before transmitting the final version of the string. The
|
|
editing function is supplied sometimes by the Forth system itself, and
|
|
sometimes by external system software or hardware. Thus, control
|
|
characters and functions may not be available on all systems. In the
|
|
usual case, the end of the editing process and final transmission of the
|
|
string is signified by the user pressing a <B>Return</B> or <B>Enter</B>
|
|
key.
|
|
|
|
<P>
|
|
|
|
As in previous standards, EXPECT returns the input string immediately
|
|
after the requested number of characters are entered, as well as when a
|
|
line terminator is received. The <B>automatic termination after
|
|
specified count of characters have been entered</B> behavior is widely
|
|
considered undesirable because the user <B>loses control</B> of the
|
|
input editing process at a potentially unknown time (the user does not
|
|
necessarily know how many characters were requested from EXPECT). Thus
|
|
EXPECT and SPAN have been made obsolescent and exist in the Standard
|
|
only as a concession to existing implementations. If EXPECT exists in a
|
|
Standard System it must have the <B>automatic termination</B> behavior.
|
|
|
|
<P>
|
|
|
|
ACCEPT does not have the <B>automatic termination</B> behavior of
|
|
EXPECT. However, because external system hardware and software may
|
|
perform the ACCEPT function, when a line terminator is received the
|
|
action of the cursor, and therefore the display, is
|
|
implementation-defined. It is recommended that the cursor remain
|
|
immediately following the entered text after a line terminator is
|
|
received.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0705>A.6.1.0705 ALIGN</A>
|
|
<P>
|
|
|
|
In this Standard we have attempted to provide transportability across
|
|
various CPU architectures. One of the frequent causes of
|
|
transportability problems is the requirement of cell-aligned addresses
|
|
on some CPUs. On these systems, ALIGN and ALIGNED may be required to
|
|
build and traverse data structures built with C,. Implementors may
|
|
define these words as no-ops on systems for which they aren't
|
|
functional.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0706>A.6.1.0706 ALIGNED</A>
|
|
<P>
|
|
<code>
|
|
See:
|
|
<a href=dpansa6.htm#A.6.1.0705>A.6.1.0705 ALIGN</a>
|
|
</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0760>A.6.1.0760 BEGIN</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
<pre>
|
|
: X ... BEGIN ... test UNTIL ;
|
|
</pre>
|
|
|
|
or
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... BEGIN ... test WHILE ... REPEAT ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0770>A.6.1.0770 BL</A>
|
|
<P>
|
|
|
|
Because space is used throughout Forth as the standard delimiter, this
|
|
word is the only way a program has to find and use the system value of
|
|
<B>space</B>. The value of a space character can not be obtained with
|
|
CHAR, for instance.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0880>A.6.1.0880 CELL+</A>
|
|
<P>
|
|
|
|
As with ALIGN and ALIGNED, the words CELL and CELL+ were added to aid in
|
|
transportability across systems with different cell sizes. They are
|
|
intended to be used in manipulating indexes and addresses in integral
|
|
numbers of cell-widths.
|
|
|
|
<P>
|
|
|
|
Example:
|
|
|
|
<PRE>
|
|
2VARIABLE DATA
|
|
|
|
0 100 DATA 2!
|
|
DATA @ . 100
|
|
|
|
DATA CELL+ @ . 0
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0890>A.6.1.0890 CELLS</A>
|
|
<P>
|
|
<code>
|
|
See:
|
|
<a href=dpansa6.htm#A.6.1.0880>A.6.1.0880 CELL+</a>
|
|
</code>
|
|
<P>
|
|
|
|
Example: <code>CREATE NUMBERS 100 CELLS ALLOT</code>
|
|
<P>
|
|
|
|
(Allots space in the array NUMBERS for 100 cells of data.)
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0895>A.6.1.0895 CHAR</A>
|
|
<P>
|
|
|
|
Typical use: <code>... CHAR A CONSTANT "A" ...</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.0950>A.6.1.0950 CONSTANT</A>
|
|
<P>
|
|
|
|
Typical use: <code>... DECIMAL 10 CONSTANT TEN ...</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1000>A.6.1.1000 CREATE</A>
|
|
<P>
|
|
|
|
The data-field address of a word defined by CREATE is given by the
|
|
data-space pointer immediately following the execution of CREATE
|
|
|
|
<P>
|
|
|
|
Reservation of data field space is typically done with ALLOT.
|
|
|
|
<P>
|
|
|
|
Typical use: <code>... CREATE SOMETHING ...</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1240>A.6.1.1240 DO</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... limit first DO ... LOOP ;
|
|
</PRE>
|
|
<P>
|
|
|
|
or
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... limit first DO ... step +LOOP ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1250>A.6.1.1250 DOES></A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... DOES> ... ;</code>
|
|
|
|
<P>
|
|
|
|
Following DOES>, a Standard Program may not make any assumptions
|
|
regarding the ability to find either the name of the definition
|
|
containing the DOES> or any previous definition whose name may be
|
|
concealed by it. DOES> effectively ends one definition and begins
|
|
another as far as local variables and control-flow structures are
|
|
concerned. The compilation behavior makes it clear that the user is not
|
|
entitled to place DOES> inside any control-flow structures.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1310>A.6.1.1310 ELSE</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... test IF ... ELSE ... THEN ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1345>A.6.1.1345 ENVIRONMENT?</A>
|
|
<P>
|
|
|
|
In a Standard System that contains only the Core word set, effective use
|
|
of ENVIRONMENT? requires either its use within a definition, or the use
|
|
of user-supplied auxiliary definitions. The Core word set lacks both a
|
|
direct method for collecting a string in interpretation state
|
|
(
|
|
<a href=dpans11.htm#11.6.1.2165>11.6.1.2165</a>
|
|
S" is in an optional word set) and also a means to test the
|
|
returned flag in interpretation state (e.g. the optional
|
|
<a href=dpans15.htm#15.6.2.2532>15.6.2.2532</a> [IF]).
|
|
|
|
<P>
|
|
|
|
The combination of
|
|
<a href=dpans6.htm#6.1.1345>6.1.1345</a> ENVIRONMENT?,
|
|
<a href=dpans11.htm#11.6.1.2165>11.6.1.2165</a> S",
|
|
<a href=dpans15.htm#15.6.2.2532>15.6.2.2532</a> [IF],
|
|
<a href=dpans15.htm#15.6.2.2531>15.6.2.2531</a> [ELSE], and
|
|
<a href=dpans15.htm#15.6.2.2533>15.6.2.2533</a> [THEN] constitutes an
|
|
effective suite of words for conditional compilation that works in
|
|
interpretation state.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1360>A.6.1.1360 EVALUATE</A>
|
|
<P>
|
|
|
|
The Technical Committee is aware that this function is commonly spelled
|
|
EVAL. However, there exist implementations that could suffer by
|
|
defining the word as is done here. We also find EVALUATE to be more
|
|
readable and explicit. There was some sentiment for calling this
|
|
INTERPRET, but that too would have undesirable effects on existing code.
|
|
The longer spelling was not deemed significant since this is not a word
|
|
that should be used frequently in source code.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1380>A.6.1.1380 EXIT</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... test IF ... EXIT THEN ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1550>A.6.1.1550 FIND</A>
|
|
<P>
|
|
|
|
One of the more difficult issues which the Committee took on was the
|
|
problem of divorcing the specification of implementation mechanisms from
|
|
the specification of the Forth language. Three basic implementation
|
|
approaches can be quickly enumerated:
|
|
|
|
<P>
|
|
|
|
1) Threaded code mechanisms. These are the traditional approaches to
|
|
implementing Forth, but other techniques may be used.
|
|
|
|
<P>
|
|
|
|
2) Subroutine threading with <B>macro-expansion</B> (code copying).
|
|
Short routines, like the code for DUP, are copied into a definition
|
|
rather than compiling a JSR reference.
|
|
|
|
<P>
|
|
|
|
3) Native coding with optimization. This may include stack optimization
|
|
(replacing such phrases as
|
|
<code>SWAP ROT +</code> with one or two machine
|
|
instructions, for example), parallelization (the trend in the newer RISC
|
|
chips is to have several functional subunits which can execute in
|
|
parallel), and so on.
|
|
|
|
<P>
|
|
|
|
The initial requirement (inherited from Forth-83) that compilation
|
|
addresses be compiled into the dictionary disallowed type 2 and type 3
|
|
implementations.
|
|
|
|
<P>
|
|
|
|
Type 3 mechanisms and optimizations of type 2 implementations were
|
|
hampered by the explicit specification of immediacy or non-immediacy of
|
|
all standard words. POSTPONE allowed de-specification of immediacy or
|
|
non-immediacy for all but a few Forth words whose behavior must be
|
|
STATE-independent.
|
|
|
|
<P>
|
|
|
|
One type 3 implementation, Charles Moore's cmForth, has both compiling
|
|
and interpreting versions of many Forth words. At the present, this
|
|
appears to be a common approach for type 3 implementations. The
|
|
Committee felt that this implementation approach must be allowed.
|
|
Consequently, it is possible that words without interpretation semantics
|
|
can be found only during compilation, and other words may exist in two
|
|
versions: a compiling version and an interpreting version. Hence the
|
|
values returned by FIND may depend on STATE, and ' and ['] may be unable
|
|
to find words without interpretation semantics.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1561>A.6.1.1561 FM/MOD</A>
|
|
<P>
|
|
|
|
By introducing the requirement for <B>floored</B> division, Forth-83
|
|
produced much controversy and concern on the part of those who preferred
|
|
the more common practice followed in other languages of implementing
|
|
division according to the behavior of the host CPU, which is most often
|
|
symmetric (rounded toward zero). In attempting to find a compromise
|
|
position, this Standard provides primitives for both common varieties,
|
|
floored and symmetric
|
|
(<a href=dpans6.htm#6.1.2214>see</a> SM/REM). FM/MOD is the floored version.
|
|
|
|
<P>
|
|
|
|
The Technical Committee considered providing two complete sets of
|
|
explicitly named division operators, and declined to do so on the
|
|
grounds that this would unduly enlarge and complicate the Standard.
|
|
Instead, implementors may define the normal division words in terms of
|
|
either FM/MOD or SM/REM providing they document their choice. People
|
|
wishing to have explicitly named sets of operators are encouraged to do
|
|
so. FM/MOD may be used, for example, to define:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: /_MOD ( n1 n2 -- n3 n4) >R S>D R> FM/MOD ;
|
|
|
|
: /_ ( n1 n2 -- n3) /_MOD SWAP DROP ;
|
|
|
|
: _MOD ( n1 n2 -- n3) /_MOD DROP ;
|
|
|
|
: */_MOD ( n1 n2 n3 -- n4 n5) >R M* R> FM/MOD ;
|
|
|
|
: */_ ( n1 n2 n3 -- n4 ) */_MOD SWAP DROP ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1700>A.6.1.1700 IF</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... test IF ... THEN ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
or
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... test IF ... ELSE ... THEN ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1710>A.6.1.1710 IMMEDIATE</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... ; IMMEDIATE</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1720>A.6.1.1720 INVERT</A>
|
|
<P>
|
|
|
|
The word NOT was originally provided in Forth as a flag operator to make
|
|
control structures readable. Under its intended usage the following two
|
|
definitions would produce identical results:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: ONE ( flag -- )
|
|
IF ." true" ELSE ." false" THEN ;
|
|
|
|
: TWO ( flag -- )
|
|
NOT IF ." false" ELSE ." true" THEN ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
This was common usage prior to the Forth-83 Standard which redefined NOT
|
|
as a cell-wide one's-complement operation, functionally equivalent to
|
|
the phrase
|
|
<code>-1 XOR</code>. At the same time, the data type manipulated by this
|
|
word was changed from a flag to a cell-wide collection of bits and the
|
|
standard value for true was changed from <B>1</B> (rightmost bit only
|
|
set) to <B>-1</B> (all bits set). As these definitions of TRUE and NOT
|
|
were incompatible with their previous definitions, many Forth users
|
|
continue to rely on the old definitions. Hence both versions are in
|
|
common use.
|
|
|
|
<P>
|
|
|
|
Therefore, usage of NOT cannot be standardized at this time. The two
|
|
traditional meanings of NOT - that of negating the sense of a flag and
|
|
that of doing a one's complement operation - are made available by 0=
|
|
and INVERT, respectively.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1730>A.6.1.1730 J</A>
|
|
<P>
|
|
|
|
J may only be used with a nested DO...LOOP, DO...+LOOP, ?DO...LOOP, or
|
|
?DO...+LOOP, for example, in the form:
|
|
|
|
|
|
<PRE>
|
|
: X ... DO ... DO ... J ... LOOP ... +LOOP ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1760>A.6.1.1760 LEAVE</A>
|
|
<P>
|
|
|
|
Note that LEAVE immediately exits the loop. No words following LEAVE
|
|
within the loop will be executed. Typical use:
|
|
|
|
|
|
<PRE>
|
|
: X ... DO ... IF ... LEAVE THEN ... LOOP ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1780>A.6.1.1780 LITERAL</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... [ x ] LITERAL ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1800>A.6.1.1800 LOOP</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... limit first DO ... LOOP ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
or
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... limit first ?DO ... LOOP ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1810>A.6.1.1810 M*</A>
|
|
<P>
|
|
|
|
This word is a useful early step in calculation, going to extra
|
|
precision conveniently. It has been in use since the Forth systems of
|
|
the early 1970's.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.1900>A.6.1.1900 MOVE</A>
|
|
<P>
|
|
|
|
CMOVE and CMOVE> are the primary move operators in Forth-83. They
|
|
specify a behavior for moving that implies propagation if the move is
|
|
suitably invoked. In some hardware, this specific behavior cannot be
|
|
achieved using the best move instruction. Further, CMOVE and CMOVE>
|
|
move characters; ANS Forth needs a move instruction capable of dealing
|
|
with address units. Thus MOVE has been defined and added to the Core
|
|
word set, and CMOVE and CMOVE> have been moved to the String word set.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2033>A.6.1.2033 POSTPONE</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: ENDIF POSTPONE THEN ; IMMEDIATE
|
|
|
|
: X ... IF ... ENDIF ... ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
POSTPONE replaces most of the functionality of
|
|
COMPILE and
|
|
<a href=dpans6.htm#6.2.2530>[COMPILE]</a>.
|
|
COMPILE and [COMPILE] are used for the same purpose: postpone the
|
|
compilation behavior of the next word in the parse area. COMPILE was
|
|
designed to be applied to non-immediate words and [COMPILE] to immediate
|
|
words. This burdens the programmer with needing to know which words in
|
|
a system are immediate. Consequently, Forth standards have had to
|
|
specify the immediacy or non-immediacy of all words covered by the
|
|
Standard. This unnecessarily constrains implementors.
|
|
|
|
<P>
|
|
|
|
A second problem with COMPILE is that some programmers have come to
|
|
expect and exploit a particular implementation, namely:
|
|
|
|
|
|
<PRE>
|
|
: COMPILE R> DUP @ , CELL+ >R ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
This implementation will not work on native code Forth systems. In a
|
|
native code Forth using inline code expansion and peephole optimization,
|
|
the size of the object code produced varies; this information is
|
|
difficult to communicate to a <B>dumb</B> COMPILE. A <B>smart</B>
|
|
(i.e., immediate) COMPILE would not have this problem, but this was
|
|
forbidden in previous standards.
|
|
|
|
<P>
|
|
|
|
For these reasons, COMPILE has not been included in the Standard and
|
|
[COMPILE] has been moved in favor of POSTPONE. Additional discussion
|
|
can be found in Hayes, J.R., <B>Postpone</B>, Proceedings of the 1989
|
|
Rochester Forth Conference.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2120>A.6.1.2120 RECURSE</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... RECURSE ... ;</code>
|
|
|
|
<P>
|
|
|
|
This is Forth's recursion operator; in some implementations it is called
|
|
MYSELF. The usual example is the coding of the factorial function.
|
|
|
|
<PRE>
|
|
: FACTORIAL ( +n1 -- +n2)
|
|
DUP 2 < IF DROP 1 EXIT THEN
|
|
DUP 1- RECURSE *
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
n2 = n1(n1-1)(n1-2)...(2)(1), the product of n1 with all positive
|
|
integers less than itself (as a special case, zero factorial equals
|
|
one). While beloved of computer scientists, recursion makes unusually
|
|
heavy use of both stacks and should therefore be used with caution. See
|
|
alternate definition in
|
|
<a href=dpansa6.htm#A.6.1.2140>A.6.1.2140</a> REPEAT.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2140>A.6.1.2140 REPEAT</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
<P>
|
|
|
|
|
|
|
|
<PRE>
|
|
: FACTORIAL ( +n1 -- +n2)
|
|
DUP 2 < IF DROP 1 EXIT THEN
|
|
DUP
|
|
BEGIN DUP 2 > WHILE
|
|
1- SWAP OVER * SWAP
|
|
REPEAT DROP
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2165>A.6.1.2165 S"</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... S" ccc" ... ;</code>
|
|
|
|
<P>
|
|
|
|
This word is found in many systems under the name " (quote). However,
|
|
current practice is almost evenly divided on the use of ", with many
|
|
systems using the execution semantics given here, while others return
|
|
the address of a counted string. We attempt here to satisfy both camps
|
|
by providing two words, S" and the Core Extension word C" so that users
|
|
may have whichever behavior they expect with a simple renaming
|
|
operation.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2214>A.6.1.2214 SM/REM</A>
|
|
<P>
|
|
|
|
See the previous discussion of division under FM/MOD. SM/REM is the
|
|
symmetric-division primitive, which allows programs to define the
|
|
following symmetric-division operators:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: /-REM ( n1 n2 -- n3 n4 ) >R S>D R> SM/REM ;
|
|
|
|
: /- ( n1 n2 -- n3 ) /-REM SWAP DROP ;
|
|
|
|
: -REM ( n1 n2 -- n3 ) /-REM DROP ;
|
|
|
|
: */-REM ( n1 n2 n3 -- n4 n5 ) >R M* R> SM/REM ;
|
|
|
|
: */- ( n1 n2 n3 -- n4 ) */-REM SWAP DROP ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2216>A.6.1.2216 SOURCE</A>
|
|
<P>
|
|
|
|
SOURCE simplifies the process of directly accessing the input buffer by
|
|
hiding the differences between its location for different input sources.
|
|
This also gives implementors more flexibility in their implementation of
|
|
buffering mechanisms for different input sources. The committee moved
|
|
away from an input buffer specification consisting of a collection of
|
|
individual variables, declaring TIB and #TIB obsolescent.
|
|
|
|
<P>
|
|
|
|
SOURCE in this form exists in F83, POLYFORTH, LMI's Forths and others.
|
|
In conventional systems it is equivalent to the phrase
|
|
|
|
|
|
<PRE>
|
|
BLK @ IF BLK @ BLOCK 1024 ELSE TIB #TIB @ THEN
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2250>A.6.1.2250 STATE</A>
|
|
<P>
|
|
|
|
Although EVALUATE, LOAD, INCLUDE-FILE, and INCLUDED are not listed as
|
|
words which alter STATE, the text interpreted by any one of these words
|
|
could include one or more words which explicitly alter STATE. EVALUATE,
|
|
LOAD, INCLUDE-FILE, and INCLUDED do not in themselves alter STATE.
|
|
|
|
<P>
|
|
|
|
STATE does not nest with text interpreter nesting. For example, the
|
|
code sequence:
|
|
|
|
|
|
<PRE>
|
|
: FOO S" ]" EVALUATE ; FOO
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
will leave the system in compilation state. Similarly, after LOADing a
|
|
block containing ], the system will be in compilation state.
|
|
|
|
<P>
|
|
|
|
Note that ] does not affect the parse area and that the only effect that
|
|
: has on the parse area is to parse a word. This entitles a program to
|
|
use these words to set the state with known side-effects on the parse
|
|
area. For example:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: NOP : POSTPONE ; IMMEDIATE ;
|
|
|
|
NOP ALIGN NOP ALIGNED
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
Some non-ANS Forth compliant systems have ] invoke a compiler loop in
|
|
addition to setting STATE. Such a system would inappropriately attempt
|
|
to compile the second use of NOP.
|
|
|
|
<P>
|
|
|
|
Also note that nothing in the Standard prevents a program from finding
|
|
the execution tokens of ] or [ and using these to affect STATE. These
|
|
facts suggest that implementations of ] will do nothing but set STATE
|
|
and a single interpreter/compiler loop will monitor STATE.
|
|
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2270>A.6.1.2270 THEN</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... test IF ... THEN ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
or
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: X ... test IF ... ELSE ... THEN ... ;
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2380>A.6.1.2380 UNLOOP</A>
|
|
<P>
|
|
|
|
|
|
Typical use:
|
|
|
|
<PRE>
|
|
: X ...
|
|
|
|
limit first DO
|
|
|
|
... test IF ... UNLOOP EXIT THEN ...
|
|
|
|
LOOP
|
|
...
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
UNLOOP allows the use of EXIT within the context of DO ... LOOP and
|
|
related do-loop constructs. UNLOOP as a function has been called UNDO.
|
|
UNLOOP is more indicative of the action: nothing gets undone -- we
|
|
simply stop doing it.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2390>A.6.1.2390 UNTIL</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... BEGIN ... test UNTIL ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2410>A.6.1.2410 VARIABLE</A>
|
|
<P>
|
|
|
|
|
|
Typical use: <code>... VARIABLE XYZ ...</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2430>A.6.1.2430 WHILE</A>
|
|
<P>
|
|
|
|
|
|
Typical use: <code>: X ... BEGIN ... test WHILE ... REPEAT ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2450>A.6.1.2450 WORD</A>
|
|
<P>
|
|
|
|
Typical use: <code>char WORD ccc<char></code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2500>A.6.1.2500 [</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... [ 4321 ] LITERAL ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2510>A.6.1.2510 [']</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... ['] name ... ;</code>
|
|
|
|
<P>
|
|
<code>
|
|
See:
|
|
<a href=dpansa6.htm#A.6.1.1550>A.6.1.1550 FIND</a>
|
|
</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2520>A.6.1.2520 [CHAR]</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... [CHAR] ccc ... ;</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.1.2540>A.6.1.2540 ]</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... [ 1234 ] LITERAL ... ;</code>
|
|
|
|
<P>
|
|
|
|
|
|
<hr>
|
|
<a name=A.6.2>
|
|
<H3>A.6.2 Core extension words</H3>
|
|
</a>
|
|
|
|
The words in this collection fall into several categories:
|
|
<P>
|
|
|
|
<UL>
|
|
<LI>Words that are in common use but are deemed less essential than Core
|
|
words (e.g.,
|
|
<a href=dpans6.htm#6.2.0260>0<></a>);
|
|
<LI>Words that are in common use but can be trivially defined from Core
|
|
words (e.g.,
|
|
<a href=dpans6.htm#6.2.1485>FALSE</a>);
|
|
<LI>Words that are primarily useful in narrowly defined types of
|
|
applications or are in less frequent use (e.g.,
|
|
<a href=dpans6.htm#6.2.2008>PARSE</a>);
|
|
<LI>Words that are being deprecated in favor of new words introduced to
|
|
solve specific problems (e.g.,
|
|
<a href=dpans6.htm#6.2.0970>CONVERT</a>).
|
|
</UL>
|
|
<P>
|
|
|
|
Because of the varied justifications for inclusion of these words, the
|
|
Technical Committee does not encourage implementors to offer the
|
|
complete collection, but to select those words deemed most valuable to
|
|
their clientele.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0060>A.6.2.0060 #TIB</A>
|
|
<P>
|
|
|
|
The function of #TIB has been superseded by
|
|
<a href=dpans6.htm#6.1.2216>SOURCE</a>.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0200>A.6.2.0200 .(</A>
|
|
<P>
|
|
|
|
Typical use: <code>.( ccc)</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0210>A.6.2.0210 .R</A>
|
|
<P>
|
|
|
|
In .R, <B>R</B> is short for RIGHT.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0340>A.6.2.0340 2>R</A>
|
|
<P>
|
|
|
|
Historically, 2>R has been used to implement
|
|
<a href=dpans6.htm#6.1.1240>DO</a>. Hence the order of
|
|
parameters on the return stack.
|
|
|
|
<P>
|
|
|
|
The primary advantage of 2>R is that it puts the top stack entry on the
|
|
top of the return stack. For instance, a double-cell number may be
|
|
transferred to the return stack and still have the most significant cell
|
|
accessible on the top of the return stack.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0410>A.6.2.0410 2R></A>
|
|
<P>
|
|
|
|
Note that 2R> is not equivalent to
|
|
<a href=dpans6.htm#6.1.2060>R></a> R>. Instead, it mirrors the
|
|
action of
|
|
<a href=dpans6.htm#6.2.0340>2>R</a>
|
|
(see <a href=dpansa6.htm#A.6.2.0340>A.6.2.0340</A>).
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0455>A.6.2.0455 :NONAME</A>
|
|
<P>
|
|
|
|
:NONAME allows a user to create an execution token with the semantics of
|
|
a colon definition without an associated name. Previously, only
|
|
<a href=dpans6.htm#6.1.0450>:</a>
|
|
(colon) could create an execution token with these semantics. Thus,
|
|
Forth code could only be compiled using the syntax of :, that is:
|
|
|
|
|
|
<PRE>
|
|
: NAME ... ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
:NONAME removes this constraint and places the Forth compiler in the
|
|
hands of the programmer.
|
|
|
|
<P>
|
|
|
|
:NONAME can be used to create application-specific programming
|
|
languages. One technique is to mix Forth code fragments with
|
|
application-specific constructs. The application-specific constructs
|
|
use :NONAME to compile the Forth code and store the corresponding
|
|
execution tokens in data structures.
|
|
|
|
<P>
|
|
|
|
The functionality of :NONAME can be built on any Forth system. For
|
|
years, expert Forth programmers have exploited intimate knowledge of
|
|
their systems to generate unnamed code fragments. Now, this function
|
|
has been named and can be used in a portable program.
|
|
|
|
<P>
|
|
|
|
For example, :NONAME can be used to build a table of code fragments
|
|
where indexing into the table allows executing a particular fragment.
|
|
The declaration syntax of the table is:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
:NONAME .. code for command 0 .. ; 0 CMD !
|
|
|
|
:NONAME .. code for command 1 .. ; 1 CMD !
|
|
...
|
|
|
|
:NONAME .. code for command 99 .. ; 99 CMD !
|
|
|
|
... 5 CMD @ EXECUTE ...
|
|
|
|
</PRE>
|
|
<P>
|
|
|
|
The definitions of the table building words are:
|
|
|
|
<PRE>
|
|
CREATE CMD-TABLE \ table for command execution tokens
|
|
100 CELLS ALLOT
|
|
|
|
: CMD ( n -- a-addr ) \ nth element address in table
|
|
CELLS CMD-TABLE + ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
As a further example, a defining word can be created to allow
|
|
performance monitoring. In the example below, the number of times a
|
|
word is executed is counted. : must first be renamed to allow the
|
|
definition of the new ;.
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
: DOCOLON ( -- ) \ Modify CREATEd word to execute like a colon def
|
|
DOES> ( i*x a-addr -- j*x )
|
|
1 OVER +! \ count executions
|
|
CELL+ @ EXECUTE \ execute :NONAME definition
|
|
;
|
|
|
|
: OLD: : ; \ just an alias
|
|
|
|
OLD: : ( "name" -- a-addr xt colon-sys )
|
|
\ begins an execution-counting colon definition
|
|
CREATE HERE 0 , \ storage for execution counter
|
|
0 , \ storage for execution token
|
|
DOCOLON \ set run time for CREATEd word
|
|
:NONAME \ begin unnamed colon definition
|
|
;
|
|
</PRE>
|
|
<P>
|
|
|
|
( Note the placement of DOES>: DOES> must modify the CREATEd word and not
|
|
the :NONAME definition, so DOES> must execute before :NONAME.)
|
|
|
|
<PRE>
|
|
OLD: ; ( a-addr xt colon-sys -- )
|
|
\ ends an execution-counting colon definition )
|
|
POSTPONE ; \ complete compilation of colon def
|
|
SWAP CELL+ ! \ save execution token
|
|
; IMMEDIATE
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
The new : and ; are used just like the standard ones to define words:
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
... : xxx ... ; ... xxx ...
|
|
</PRE>
|
|
|
|
Now however, these words may be <B>ticked</B> to retrieve the count (and
|
|
execution token):
|
|
|
|
|
|
<PRE>
|
|
... ' xxx >BODY ? ...
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0620>A.6.2.0620 ?DO</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<code>: FACTORIAL ( +n1 -- +n2 ) 1 SWAP 1+ ?DO I * LOOP ;</code>
|
|
|
|
<P>
|
|
|
|
This word was added in response to many requests for a resolution of the
|
|
difficulty introduced by Forth-83's DO, which on a 16-bit system will
|
|
loop 65,535 times if given equal arguments. As this Standard also
|
|
encourages 32-bit systems, this behavior can be intolerable. The
|
|
Technical Committee considered applying these semantics to
|
|
<a href=dpans6.htm#6.1.1240>DO</a>, but
|
|
declined on the grounds that it might break existing code.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0700>A.6.2.0700 AGAIN</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... BEGIN ... AGAIN ... ;</code>
|
|
|
|
<P>
|
|
|
|
Unless word-sequence has a way to terminate, this is an endless loop.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0855>A.6.2.0855 C"</A>
|
|
<P>
|
|
|
|
Typical use: <code>: X ... C" ccc" ... ;</code>
|
|
|
|
<P>
|
|
|
|
It is easy to convert counted strings to pointer/length but hard to do
|
|
the opposite. C" is the only new word that uses the <B>address of
|
|
counted string</B> stack representation. It is provided as an aid to
|
|
porting existing programs to ANS Forth systems. It is relatively
|
|
difficult to implement C" in terms of other standard words, considering
|
|
its <B>compile string into the current definition</B> semantics.
|
|
|
|
<P>
|
|
|
|
Users of C" are encouraged to migrate their application code toward the
|
|
consistent use of the preferred <B>c-addr u</B> stack representation
|
|
with the alternate word
|
|
<a href=dpans6.htm#6.1.2165>S"</a>. This may be accomplished by converting
|
|
application words with counted string input arguments to use the
|
|
preferred <B>c-addr u</B> representation, thus eliminating the need for
|
|
C" .
|
|
|
|
<P>
|
|
<code>
|
|
See:
|
|
<a href=dpansa3.htm#A.3.1.3.4>A.3.1.3.4</a> Counted strings
|
|
</code>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0873>A.6.2.0873 CASE</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<PRE>
|
|
: X ...
|
|
CASE
|
|
test1 OF ... ENDOF
|
|
testn OF ... ENDOF
|
|
... ( default )
|
|
ENDCASE ...
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0945>A.6.2.0945 COMPILE,</A>
|
|
<P>
|
|
|
|
COMPILE, is the compilation equivalent of
|
|
<a href=dpans6.htm#6.1.1370>EXECUTE</a>. In many cases, it is
|
|
possible to compile a word by using
|
|
<a href=dpans6.htm#6.1.2033>POSTPONE</a> without resorting to the
|
|
use of COMPILE,. However, the use of POSTPONE requires that the name of
|
|
the word must be known at compile time, whereas COMPILE, allows the word
|
|
to be located at any time. It is sometime possible to use
|
|
<a href=dpans6.htm#6.1.1360>EVALUATE</a> to
|
|
compile a word whose name is not known until run time. This has two
|
|
possible problems:
|
|
|
|
<UL>
|
|
<LI>EVALUATE is slower than COMPILE, because a dictionary search is
|
|
required.
|
|
<LI>The current search order affects the outcome of EVALUATE.
|
|
</UL>
|
|
<P>
|
|
|
|
In traditional threaded-code implementations, compilation is performed
|
|
by
|
|
<a href=dpans6.htm#6.1.0150>,</a> (comma).
|
|
This usage is not portable; it doesn't work for
|
|
subroutine-threaded, native code, or relocatable implementations. Use
|
|
of COMPILE, is portable.
|
|
|
|
<P>
|
|
|
|
In most systems it is possible to implement COMPILE, so it will generate
|
|
code that is optimized to the same extent as code that is generated by
|
|
the normal compilation process. However, in some implementations there
|
|
are two different <B>tokens</B> corresponding to a particular definition
|
|
name: the normal <B>execution token</B> that is used while interpreting
|
|
or with EXECUTE, and another <B>compilation token</B> that is used while
|
|
compiling. It is not always possible to obtain the compilation token
|
|
from the execution token. In these implementations, COMPILE, might not
|
|
generate code that is as efficient as normally compiled code.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.0970>A.6.2.0970 CONVERT</A>
|
|
<P>
|
|
|
|
CONVERT may be defined as follows:
|
|
|
|
|
|
<PRE>
|
|
: CONVERT CHAR+ 65535 >NUMBER DROP ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.1342>A.6.2.1342 ENDCASE</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<PRE>
|
|
: X ...
|
|
CASE
|
|
test1 OF ... ENDOF
|
|
testn OF ... ENDOF
|
|
... ( default )
|
|
ENDCASE ...
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.1343>A.6.2.1343 ENDOF</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<PRE>
|
|
: X ...
|
|
CASE
|
|
test1 OF ... ENDOF
|
|
testn OF ... ENDOF
|
|
... ( default )
|
|
ENDCASE ...
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.1390>A.6.2.1390 EXPECT</A>
|
|
<P>
|
|
|
|
Specification of positive integer counts (+n) for EXPECT allows some
|
|
implementors to continue their practice of using a zero or negative
|
|
value as a flag to trigger special behavior. Insofar as such behavior
|
|
is outside the Standard, Standard Programs cannot depend upon it, but
|
|
the Technical Committee doesn't wish to preclude it unnecessarily.
|
|
Since actual values are almost always small integers, no functionality
|
|
is impaired by this restriction.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.1850>A.6.2.1850 MARKER</A>
|
|
<P>
|
|
|
|
As dictionary implementations have gotten more elaborate and in some
|
|
cases have used multiple address spaces,
|
|
<a href=dpans15.htm#15.6.2.1580>FORGET</a> has become prohibitively
|
|
difficult or impossible to implement on many Forth systems. MARKER
|
|
greatly eases the problem by making it possible for the system to
|
|
remember <B>landmark information</B> in advance that specifically marks
|
|
the spots where the dictionary may at some future time have to be
|
|
rearranged.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.1950>A.6.2.1950 OF</a>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<PRE>
|
|
: X ...
|
|
CASE
|
|
test1 OF ... ENDOF
|
|
testn OF ... ENDOF
|
|
... ( default )
|
|
ENDCASE ...
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2000>A.6.2.2000 PAD</A>
|
|
<P>
|
|
|
|
PAD has been available as scratch storage for strings since the earliest
|
|
Forth implementations. It was brought to our attention that many
|
|
programmers are reluctant to use PAD, fearing incompatibilities with
|
|
system uses. PAD is specifically intended as a programmer convenience,
|
|
however, which is why we documented the fact that no standard words use
|
|
it.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2008>A.6.2.2008 PARSE</A>
|
|
<P>
|
|
|
|
Typical use: <code>char PARSE ccc<char></code>
|
|
|
|
<P>
|
|
|
|
The traditional Forth word for parsing is
|
|
<a href=dpans6.htm#6.1.2450>WORD</a>. PARSE solves the
|
|
following problems with WORD:
|
|
|
|
<P>
|
|
|
|
a) WORD always skips leading delimiters. This behavior is appropriate
|
|
for use by the text interpreter, which looks for sequences of non-blank
|
|
characters, but is inappropriate for use by words like ( , .( , and ." .
|
|
Consider the following (flawed) definition of .( :
|
|
|
|
|
|
<PRE>
|
|
: .( [CHAR] ) WORD COUNT TYPE ; IMMEDIATE
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
This works fine when used in a line like:
|
|
|
|
|
|
<PRE>
|
|
.( HELLO) 5 .
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
but consider what happens if the user enters an empty string:
|
|
|
|
|
|
<PRE>
|
|
.( ) 5 .
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
The definition of .( shown above would treat the ) as a leading
|
|
delimiter, skip it, and continue consuming characters until it located
|
|
another ) that followed a non-) character, or until the parse area was
|
|
empty. In the example shown, the 5 . would be treated as part of the
|
|
string to be printed.
|
|
|
|
<P>
|
|
|
|
With PARSE, we could write a correct definition of .( :
|
|
|
|
|
|
<PRE>
|
|
: .( [CHAR] ) PARSE TYPE ; IMMEDIATE
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
This definition avoids the <B>empty string</B> anomaly.
|
|
|
|
<P>
|
|
|
|
b) WORD returns its result as a counted string. This has four bad
|
|
effects:
|
|
|
|
<P>
|
|
|
|
1) The characters accepted by WORD must be copied from the input buffer
|
|
into a temporary buffer, in order to make room for the count character that
|
|
must be at the beginning of the counted string. The copy step is inefficient,
|
|
compared to PARSE, which leaves the string in the input buffer and doesn't
|
|
need to copy it anywhere.
|
|
|
|
<P>
|
|
|
|
2) WORD must be careful not to store too many characters into the
|
|
temporary buffer, thus overwriting something beyond the end of the buffer.
|
|
This adds to the overhead of the copy step. (WORD may have to scan a lot of
|
|
characters before finding the trailing delimiter.)
|
|
|
|
<P>
|
|
|
|
3) The count character limits the length of the string returned by WORD
|
|
to 255 characters (longer strings can easily be stored in blocks!). This
|
|
limitation does not exist for PARSE.
|
|
|
|
<P>
|
|
|
|
4) The temporary buffer is typically overwritten by the next use of WORD.
|
|
This introduces a temporal dependency; the value returned by WORD is only
|
|
valid for a limited duration. PARSE has a temporal dependency, too, related
|
|
to the lifetime of the input buffer, but that is less severe in most cases
|
|
than WORD's temporal dependency.
|
|
|
|
<P>
|
|
|
|
The behavior of WORD with respect to skipping leading delimiters is
|
|
useful for parsing blank-delimited names. Many system implementations
|
|
include an additional word for this purpose, similar to PARSE with
|
|
respect to the <B>c-addr u</B> return value, but without an explicit
|
|
delimiter argument (the delimiter set is implicitly <B>white space</B>),
|
|
and which does skip leading delimiters. A common description for this
|
|
word is:
|
|
|
|
|
|
<PRE>
|
|
PARSE-WORD ( <spaces>name -- c-addr u )
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
Skip leading spaces and parse name delimited by a space. c-addr is the
|
|
address within the input buffer and u is the length of the selected string.
|
|
If the parse area is empty, the resulting string has a zero length.
|
|
|
|
<P>
|
|
|
|
If both PARSE and PARSE-WORD are present, the need for WORD is largely
|
|
eliminated.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2030>A.6.2.2030 PICK</A>
|
|
<P>
|
|
|
|
0 PICK is equivalent to
|
|
<a href=dpans6.htm#6.1.1290>DUP</a> and 1 PICK is equivalent to
|
|
<a href=dpans6.htm#6.1.1990>OVER</a>.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2040>A.6.2.2040 QUERY</A>
|
|
<P>
|
|
|
|
The function of QUERY may be performed with
|
|
<a href=dpans6.htm#6.1.0695>ACCEPT</a> and
|
|
<a href=dpans6.htm#6.1.1360>EVALUATE</a>.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2125>A.6.2.2125 REFILL</A>
|
|
<P>
|
|
|
|
This word is a useful generalization of
|
|
<a href=dpans6.htm#6.2.2040>QUERY</a>. Re-defining QUERY to
|
|
meet this specification would have broken existing code. REFILL is
|
|
designed to behave reasonably for all possible input sources. If the
|
|
input source is coming from the user, as with QUERY, REFILL could still
|
|
return a false value if, for instance, a communication channel closes so
|
|
that the system knows that no more input will be available.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2150>A.6.2.2150 ROLL</A>
|
|
<P>
|
|
|
|
2 ROLL is equivalent to
|
|
<a href=dpans6.htm#6.1.2160>ROT</a>,
|
|
1 ROLL is equivalent to
|
|
<a href=dpans6.htm#6.1.2260>SWAP</a> and 0 ROLL is
|
|
a null operation.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2182>A.6.2.2182 SAVE-INPUT</A>
|
|
<P>
|
|
|
|
SAVE-INPUT and
|
|
<a href=dpans6.htm#6.2.2148>RESTORE-INPUT</a>
|
|
allow the same degree of input source
|
|
repositioning within a text file as is available with
|
|
<a href=dpans7.htm#7.6.1.0800>BLOCK</a> input.
|
|
SAVE-INPUT and RESTORE-INPUT <B>hide the details</B> of the operations
|
|
necessary to accomplish this repositioning, and are used the same way
|
|
with all input sources. This makes it easier for programs to reposition
|
|
the input source, because they do not have to inspect several variables
|
|
and take different action depending on the values of those variables.
|
|
|
|
<P>
|
|
|
|
SAVE-INPUT and RESTORE-INPUT are intended for repositioning within a
|
|
single input source; for example, the following scenario is NOT allowed
|
|
for a Standard Program:
|
|
|
|
<PRE>
|
|
: XX
|
|
SAVE-INPUT CREATE
|
|
S" RESTORE-INPUT" EVALUATE
|
|
ABORT" couldn't restore input"
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
This is incorrect because, at the time RESTORE-INPUT is executed, the
|
|
input source is the string via
|
|
<a href=dpans6.htm#6.1.1360>EVALUATE</a>, which is not the same input
|
|
source that was in effect when SAVE-INPUT was executed.
|
|
|
|
<P>
|
|
|
|
The following code is allowed:
|
|
|
|
|
|
<PRE>
|
|
: XX
|
|
SAVE-INPUT CREATE
|
|
S" .( Hello)" EVALUATE
|
|
RESTORE-INPUT ABORT" couldn't restore input"
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
After EVALUATE returns, the input source specification is restored to
|
|
its previous state, thus SAVE-INPUT and RESTORE-INPUT are called with
|
|
the same input source in effect.
|
|
|
|
<P>
|
|
|
|
In the above examples, the EVALUATE phrase could have been replaced by a
|
|
phrase involving
|
|
<a href=dpans11.htm#11.6.1.1717>INCLUDE-FILE</a>
|
|
and the same rules would apply.
|
|
|
|
<P>
|
|
|
|
The Standard does not specify what happens if a program violates the
|
|
above rules. A Standard System might check for the violation and return
|
|
an exception indication from RESTORE-INPUT, or it might fail in an
|
|
unpredictable way.
|
|
|
|
<P>
|
|
|
|
The return value from RESTORE-INPUT is primarily intended to report the
|
|
case where the program attempts to restore the position of an input
|
|
source whose position cannot be restored. The keyboard might be such an
|
|
input source.
|
|
|
|
<P>
|
|
|
|
Nesting of SAVE-INPUT and RESTORE-INPUT is allowed. For example, the
|
|
following situation works as expected:
|
|
|
|
<PRE>
|
|
: XX
|
|
SAVE-INPUT
|
|
S" f1" INCLUDED \ The file "f1" includes:
|
|
\ ... SAVE-INPUT ... RESTORE-INPUT ...
|
|
\ End of file "f1"
|
|
RESTORE-INPUT ABORT" couldn't restore input"
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
In principle, RESTORE-INPUT could be implemented to <B>always fail</B>, e.g.:
|
|
|
|
<PRE>
|
|
: RESTORE-INPUT ( x1 ... xn n -- flag )
|
|
0 ?DO DROP LOOP TRUE
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
Such an implementation would not be useful in most cases. It would be
|
|
preferable for a system to leave SAVE-INPUT and RESTORE-INPUT undefined,
|
|
rather than to create a useless implementation. In the absence of the
|
|
words, the application programmer could choose whether or not to create
|
|
<B>dummy</B> implementations or to work-around the problem in some other
|
|
way.
|
|
|
|
<P>
|
|
|
|
Examples of how an implementation might use the return values from
|
|
SAVE-INPUT to accomplish the save/restore function:
|
|
|
|
<P>
|
|
|
|
|
|
<PRE>
|
|
Input Source possible stack values
|
|
------------ ---------------------
|
|
block >IN @ BLK @ 2
|
|
EVALUATE >IN @ 1
|
|
keyboard >IN @ 1
|
|
text file >IN @ lo-pos hi-pos 3
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
These are examples only; a Standard Program may not assume any particular
|
|
meaning for the individual stack items returned by SAVE-INPUT.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2290>A.6.2.2290 TIB</A>
|
|
<P>
|
|
|
|
The function of TIB has been superseded by
|
|
<a href=dpans6.htm#6.1.2216>SOURCE</a>.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2295>A.6.2.2295 TO</A>
|
|
<P>
|
|
|
|
Historically, some implementations of TO have not explicitly parsed.
|
|
Instead, they set a mode flag that is tested by the subsequent execution
|
|
of name. ANS Forth explicitly requires that TO must parse, so that TO's
|
|
effect will be predictable when it is used at the end of the parse area.
|
|
|
|
<P>
|
|
|
|
Typical use: <code>x TO name</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2298>A.6.2.2298 TRUE</A>
|
|
<P>
|
|
|
|
TRUE is equivalent to the phrase <code>0 0=</code>.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2405>A.6.2.2405 VALUE</A>
|
|
<P>
|
|
|
|
Typical use:
|
|
|
|
<PRE>
|
|
0 VALUE DATA
|
|
|
|
: EXCHANGE ( n1 -- n2 ) DATA SWAP TO DATA ;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
EXCHANGE leaves n1 in DATA and returns the prior value n2.
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2440>A.6.2.2440 WITHIN</A>
|
|
<P>
|
|
|
|
We describe WITHIN without mentioning circular number spaces (an
|
|
undefined term) or providing the code. Here is a number line with the
|
|
overflow point (o) at the far right and the underflow point (u) at the
|
|
far left:
|
|
|
|
<PRE>
|
|
u--------------------------------------------------------------o
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
There are two cases to consider: either the n2|u2..n3|u3 range straddles
|
|
the overflow/underflow points or it does not. Lets examine the
|
|
non-straddle case first:
|
|
|
|
<PRE>
|
|
u-------------------[.....................)------------------------o
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
The [ denotes n2|u2, the ) denotes n3|u3, and the dots and [ are numbers
|
|
WITHIN the range. n3|u3 is greater than n2|u2, so the following tests
|
|
will determine if n1|u1 is WITHIN n2|u2 and n3|u3:
|
|
|
|
<p>
|
|
<pre>
|
|
n2|u2 < n1|u1 and n1|u1 < n3|u3.
|
|
</pre>
|
|
<P>
|
|
|
|
In the case where the comparison range straddles the overflow/underflow
|
|
points:
|
|
<P>
|
|
|
|
u...............)-----------------------------[........................o
|
|
|
|
<p>
|
|
|
|
n3|u3 is less than n2|u2 and the following tests will determine if n1|u1 is
|
|
WITHIN n2|u2 and n3|u3:
|
|
|
|
<P>
|
|
<pre>
|
|
n2|u2 > n1|u1 and n1|u1 > n3|u3.
|
|
</pre>
|
|
<P>
|
|
|
|
|
|
WITHIN must work for both signed and unsigned arguments. One obvious
|
|
implementation does not work:
|
|
|
|
<PRE>
|
|
: WITHIN ( test low high -- flag )
|
|
>R OVER < 0= ( test flag1 )
|
|
SWAP R> < ( flag1 flag2 )
|
|
AND
|
|
;
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
Assume two's-complement arithmetic on a 16-bit machine, and consider the
|
|
following test:
|
|
|
|
|
|
<PRE>
|
|
33000 32000 34000 WITHIN
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
The above implementation returns false for that test, even though the
|
|
unsigned number 33000 is clearly within the range {{32000 .. 34000}}.
|
|
|
|
<P>
|
|
|
|
The problem is that, in the incorrect implementation, the signed
|
|
comparison
|
|
< gives the wrong answer when 32000 is compared to 33000,
|
|
because when those numbers are treated as signed numbers, 33000 is
|
|
treated as negative 32536, while 32000 remains positive.
|
|
|
|
<P>
|
|
|
|
Replacing < with
|
|
<a href=dpans6.htm#6.1.2340>U<</a>
|
|
in the above implementation makes it work with
|
|
unsigned numbers, but causes problems with certain signed number ranges;
|
|
in particular, the test:
|
|
|
|
|
|
<PRE>
|
|
1 -5 5 WITHIN
|
|
</PRE>
|
|
|
|
<P>
|
|
|
|
would give an incorrect answer.
|
|
|
|
<P>
|
|
|
|
For two's-complement machines that ignore arithmetic overflow (most
|
|
machines), the following implementation works in all cases:
|
|
|
|
<PRE>
|
|
: WITHIN ( test low high -- flag ) OVER - >R - R> U< ;
|
|
|
|
</PRE>
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2530>A.6.2.2530 [COMPILE]</A>
|
|
<P>
|
|
|
|
Typical use: <code>: name2 ... [COMPILE] name1 ... ; IMMEDIATE</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a name=A.6.2.2535>A.6.2.2535 \</A>
|
|
<P>
|
|
|
|
Typical use: <code>5 CONSTANT THAT \ THIS IS A COMMENT ABOUT THAT</code>
|
|
|
|
<P>
|
|
|
|
<hr>
|
|
<a href=dpans.htm#toc><IMG src="up.gif" ></A> Table of Contents
|
|
<BR>
|
|
<a href=dpansa7.htm><IMG src="right.gif" ></A>
|
|
Next Section
|
|
<P>
|
|
</BODY>
|
|